| Variation ID | Pack Size | List Price | Qty | ||
|---|---|---|---|---|---|
| photo_camera | 1 Pack
HI-98193 |
£1006.60 |
The HI-98193 portable dissolved oxygen meter has extended ranges of up to 50 ppm and 600% saturation. When measuring dissolved oxygen, compensations for salinity, temperature and pressure are essential to improve the accuracy and precision of readings.
Salinity compensation allows for direct determination of dissolved oxygen in saline waters. Temperature compensation is automatic with the probes built-in sensor, which features a one or two-point calibration. Pressure compensation with the meter's built-in barometer can be validated against a reference barometer, and if needed, can be recalibrated in user-selectable units (mmHg, inHg, atm, psi, kPa, mbar). With the internal barometer, the HI-98193 is able to compensate for changes in barometric pressure so there is no need for charts, altitude information or external barometric pressure information.
Other features include measurement, methods and calculations for BOD, OUR and SOUR.
Quick connect probe
The HI-764073 polarographic dissolved oxygen probe features a quick connect DIN connector to make attaching and removing the probe simple and easy.
Data Logging
The HI-98193's log-on demand features allows users to store up to 400 samples that can be later transferred to a PC with the HI-920015 USB cable and HI-92000 software.
GLP and On-Screen Help
Comprehensive GL data is directly accessible by pressing the GLP key; the contextual help menu can be accessed to obtain on-screen information and assistance at the touch of a button.
PC Interface - Download test results to a computer programmed with HANNA’s Windows® compatible software (HI-92000), directly from equipment via a USB port or a RS232 cable outlet.
| DO Range | 0.00 to 50.00 mg/L (ppm); 0.0 to 600.0% saturation |
| Resolution | 0.01 mg/L (ppm); 0.1% saturation |
| Accuracy @25°C | ±1.5% of reading ±1 digit |
| Calibration | automatic one or two point at 100% (8.26 mg/L) and 0 % (0mg/L); manual one point using a value entered by the user in % saturation or mg/L |
| Atmospheric Pressure - Range | 450 to 850 mmHg |
| Resolution | 1 mmHg |
| Accuracy @ 25°C | ±3 mmHg within ±15% from the calibration point |
| Calibration | one point at any in range pressure value |
| Temperature Range | -20.0 to 120.0°C |
| Resolution | 0.1°C |
| Accuracy @25°C | ±0.2°C (excluding probe error) |
| Calibration | one or two point at any in range temperature value |
| Additional Specifications - Measurement Modes | DO; BOD; OUR; SOUR |
| Barometric Compensation | automatic from 450 to 850 mmHg |
| Salinity Compensation | automatic from 0 to 70 g/L |
| Temperature Compensation | automatic from 0.0 to 50.0°C |
| Probe | HI-764073 polarographic DO probe with protective sleeve, internal temperature sensor, DIN connector and 4m cable (included) |
| Logging | log-on demand up to 400 samples |
| PC Connectivity | opto-isolated USB (with HI-92000 software) |
| Battery Type/Life | 1.5V AA batteries (4)/ approximately 200 hours of continuous use without backlight (50 hours with backlight) |
| Auto-off | user-selectable: 5, 10, 30, 60 min or can be displayed |
| Environment | 0 to 50°C; RH 100% IP67 |
| Dimensions | 185 x 93 x 35.2 mm |
| Weight | 400g |
| Ordering Information: | HI-98193 is supplied with HI-764073 DO probe (4m cable), preformed PTFE membrane cap (2), HI-7041S electrolyte solution (30 mL), HI-7040 bicomponent zero oxygen solution, 100 mL plastic beakers (2), HI-92000 PC software, HI-920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, instrument quality certificate and HI-760193 rugged carrying case. |