Variation ID | Pack Size | List Price | Qty | ||
---|---|---|---|---|---|
photo_camera | 13mm x 100 Pack
A1300-100 |
£40.39 | |||
photo_camera | 21mm x 100 Pack
A2100-100 |
£42.47 | |||
photo_camera | 24mm x 100 Pack
A2400-100 |
£43.40 | |||
photo_camera | 25mm x 100 Pack
A2500-100 |
£43.40 | |||
photo_camera | 35mm x 100 Pack
A3500-100 |
£43.40 | |||
photo_camera | 37mm x 100 Pack
A3700-100 |
£50.82 | |||
photo_camera | 42.5mm x 100 Pack
A4250-100 |
£54.08 | |||
photo_camera | 47mm x 100 Pack
A4700-100 |
£57.69 | |||
photo_camera | 55mm x 100 Pack
A5500-100 |
£63.49 | |||
photo_camera | 70mm x 100 Pack
A7000-100 |
£58.75 | |||
photo_camera | 90mm x 100 Pack
A9000-100 |
£91.28 | |||
photo_camera | 110mm x 100 Pack
A1100-100 |
£114.17 | |||
photo_camera | 125mm x 100 Pack
A1250-100 |
£143.76 | |||
photo_camera | 142mm x 100 Pack
A1420-100 |
£140.44 | |||
photo_camera | 150mm x 100 Pack
A1500-100 |
£162.81 |
Sterlitech Grade A Glass Fibre Filters – Fine Porosity Filters for Protein Filtration and Airborne Particulate Monitoring
Sterlitech Grade A glass fibre filters are binderless borosilicate microglass filters with fine porosity, fast flow rates, and a nominal retention of 1.6 µm. Widely used in protein and cell filtration, these filters are also ideal for radioimmunoassay (RIA) of weak beta emitters by scintillation counting, and for the gravimetric analysis of airborne particulates.
The absence of binders ensures high purity and low extractables, making Grade A a reliable choice for analytical workflows requiring both precision and minimal background interference.
Binderless borosilicate glass microfiber construction
Fine porosity with 1.6 µm nominal retention
Fast flow rate: 12 mL/min/cm²
High thermal stability up to 475°C
Thickness: 0.3 mm | Weight: 55 g/m²
Filtration of precipitated proteins and cells
Scintillation counting for beta emitters (RIA)
Gravimetric determination of airborne particulates
General analytical and environmental testing
Whatman Equivalent: GF/A
Filtration of precipitated proteins and cells
Scintillation counting for beta emitters (RIA)
Gravimetric determination of airborne particulates
General analytical and environmental testing
Specification
Grade: Grade A
Features & Applications: Precipitate proteins and cell filtration, scintilliation counting, determination of airborne particulate
Nominal Retention: 1.6 µm
Thickness: 0.3mm
Weight (g/m²): 55
Water Flow a: 12
Max. Op. Temp.: 475°C
Binder: None
Whatman Equivalent: GF/A
a The time in seconds to filter 100 ml of distilled H20 at 20°C under pressure supplied by a 10 cm water column through a 10 cm² section of filter
HS Code / Commodity Code: 7019905140