| Variation ID | Pack Size | List Price | Qty | ||
|---|---|---|---|---|---|
| photo_camera | 1 Pack
HI-97106 |
£416.30 |
The HI-97106 is a waterproof portable photometer with an advanced optical system that uses a Light Emitting Diode and a narrow band interference filter for accurate, repeatable readings.
The optical system is sealed from outside dust, dirt, and water. The meter uses an exclusive positive-locking system to ensure that the vials are placed into the holder in the same position every time.
With the CAL Check™ functionality, users are able to validate instrument performance at any time. Hanna Instrument’s CAL Check cuvettes are certified against NIST-traceable reference instruments.
The built-in tutorial mode guides users step-by-step through the measurement process. The tutorial mode includes all steps required for sample preparation, the required reagents, and quantities.
CAL Check™ validation - Validate instrument performance at any time using CAL Check™ cuvettes made with NIST traceable standards.
Removable vial adapter - The vial adapter can be removed to accommodate HI-97106-11 CAL Check™ cuvettes for validation.
On-Screen guides - Step-by-step on-screen guidance.
Auto-data logging - Data autolog helps users keep track of all measurements. Data is automatically saved every time a measurement is made. The data log can hold 200 individual measurements. When the data log is full, the meter will rewrite the oldest data point.
Waterproof and floating, IP67 meter design
Method and Parameter – The chosen parameter and method used is displayed on-screen along with the reading.
You can also see the battery status indicator and auto-shut off - The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.
Virtual keys - Menu available at the touch of a button
Dedicated help - A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.
Hanna equipment can be used in the laboratory or for on-site testing. Examples include: power plant operations, chemical manufacture, commercial laundries, pulp and paper mills, agriculture, environmental studies and general education, plus the water companies in the UK for wastewater and drinking water, and the food industry.
Chemical Oxygen Demand is a measurement of the biologically available and inert organic matter that is susceptible to oxidation by a strong oxidising agent.
The Hanna COD method is based on the well-established closed dichromate-reflux colorimetric method. The colorimetric measurement of COD is faster and easier to perform than the titrimetric analysis.
The advantages of using this method includes certifiable results as well as high accuracy.
COD is used to measure pollutants. It is normally measured in both municipal and industrial wastewater treatment plants and gives an indication of the efficiency of the treatment process. COD is measured on both influent and effluent water.
| Chemical Oxygen Demand Low Range | ||
| Range | 0 to 150 mg/L (as O₂) | |
| Resolution | 1 mg/L | |
| Accuracy | ±5 mg/L or ±4 % of reading at 25°C, whichever is greater | |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters | |
| LED | 420 nm |
| Chemical Oxygen Demand Medium Range | |
| Range | 0 to 1500 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±15 mg/L or ±4 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Chemical Oxygen Demand High Range | |
| Range | 0 to 15000 mg/L (as O₂) |
| Resolution | 1 mg/L |
| Accuracy | ±150 mg/L or ±2 % of reading at 25 °C, whichever is greater |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Chemical Oxygen Demand UHR | |
| Range | 0 to 60.0 g/L (as O₂) |
| Resolution | 0.1 g/L |
| Accuracy | ±0.5 g/L ±3 % of reading at 25 °C |
| Method | Adaptation of the US EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters |
| LED | 610 nm |
| Measurement system | |
| Light source | LED |
| Bandpass filter | wavelength 420 nm & 610 nm; bandwidth 8 nm; wavelength accuracy ±1.0 nm |
| Light detector | silicon photocell |
| Cuvette Type | round, 16 mm diameter |
| Photometer Specifications | |
| Auto logging | 200 readings |
| Display | 128 x 64 pixel B/W LCD with backlight |
| Auto-off | After 15 minutes of inactivity (after 30 minutes of inactivity if a Zero has been done but not a read) |
| Battery type / Life | 1.5 V AA alkaline (3 pcs.) / > 10000 measurements (without backlight) |
| Environment | 0 to 50 °C (32 to 122 °F); 0 to 100 % RH, non-serviceable |
| Dimensions | 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0") |
| Weight | 380 g (13.4 oz.); with batteries |
| Casing | IP67 rating, floating |