Ammonia High Range Checker HC

Ammonia High Range Checker HC Group Picture
Code: HI-733
  Pack Size List Price Qty  
photo_camera 1 Pack
HI-733
£90.20
Pack: 1 Pack

£90.20

The HI-733 Checker is a simple, accurate, and cost effective way to measure high ranges of ammonia in fresh water.

Designed as a more accurate alternative to chemical test kits, the HI-733 provides quick, accurate results in four easy steps.

The HI-733 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

Ideal for:

  • Water Quality
  • Education
  • Wastewater
  • Freshwater Aquariums
  • Environmental

Features

  • Palm-sized design
  • ±1.0ppm ±5% of reading
  • Dedicated to a single parameter
  • Uses a single AAA battery
  • Auto Power Off after 10 minutes in inactivity
  • Built-in timer for timed reaction readings

Order Information:

The HI-733 Checker HC is supplied with 2 cuvettes and caps, ammonia HR reagent starter kit x 10 tests (reorder no.: HI-733-25 x 20 tests), syringe with tip, plastic pipette, 1 x1.5V AAA battery, instruction manual and quick start guide.

Range 0.0 to 99.9 ppm as NH4+
Resolution 0.1 ppm
Accuracy (@20°C/68°F) ±1.0ppm ±5% of reading
Measurement Method Colorimetric
Light Source LED @470 nm
Light Detector Silicon photocell
Method Adaptation of the ASTM Manual of water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Power Supply Battery - 1 x 1.5V AAA
Power Auto Off After 10 min. of inactivity
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
Ordering information: Supplied with sample cuvettes with caps (2), Ammonia HR reagent starter kit (reagents for 10 tests), syringe with tip, plastic pipette, battery, instructions and quick start guide.
PLEASE NOTE: In some cases, samples may contain other parameters which may interfere with results
 Interference may be caused by: Acetone
Alcohols
Aldehydes
Glycine
Hardness above 1 g/L
Iron
Organic chloramines
Sulphide
Various aliphatic and aromatic amines