Glass Fiber Membrane Filters, GF-75, 13mm - 293mm

Glass Fiber Membrane Filters, GF-75, 13mm - 293mm Group Picture

£119.16 to £1487.59

Code: Please choose option from drop down above
  Pack Size List Price Qty  
photo_camera 13mm x 100 Pack
GF7513MM-100
£119.16
photo_camera 20mm x 100 Pack
GF7520MM-100
£119.16
photo_camera 21mm x 100 Pack
GF7521MM-100
£119.16
photo_camera 22mm x 100 Pack
GF7522MM-100
£119.16
photo_camera 24mm x 100 Pack
GF7524MM-100
£119.16
photo_camera 25mm x 100 Pack
GF7525MM-100
£119.16
photo_camera 37mm x 100 Pack
GF7537MM-100
£150.02
photo_camera 42.5mm x 100 Pack
GF7542.5MM-100
£166.15
photo_camera 47mm x 100 Pack
GF7547MM-100
£157.25
photo_camera 55mm x 100 Pack
GF7555MM-100
£213.93
photo_camera 70mm x 100 Pack
GF7570MM-100
£239.17
photo_camera 90mm x 100 Pack
GF7590MM-100
£326.34
photo_camera 110mm x 100 Pack
GF75110MM-100
£481.18
photo_camera 125mm x 100 Pack
GF75125MM-100
£585.49
photo_camera 142mm x 100 Pack
GF75142MM-100
£698.95
photo_camera 150mm x 100 Pack
GF75150MM-100
£837.86
photo_camera 293mm x 50 Pack
GF75293MM-50
£1487.59

Advantec GF-75 Glass Fibre Filters – High Retention Filters for Protein Collection and TCLP Analysis

Advantec GF-75 glass fibre filters are binderless, fine-porosity filters designed for very fine particulate retention, including IgC collection, protein precipitates, and the clarification of chemically aggressive solutions. With a nominal retention of 0.3 µm, GF-75 is the highest retention grade in the Advantec range and is well-suited for applications where precision and purity are critical.

These filters meet the requirements of EPA Method 1311 (TCLP) and are comparable to Sterlitech Grade F and Millipore APFF. The binderless borosilicate construction ensures low extractables and thermal stability up to 500°C, making them ideal for both analytical and regulatory testing environments.

Key Features

  • Binderless glass microfiber for high purity

  • Fine porosity with 0.3 µm nominal retention

  • Highest retention grade in the Advantec range

  • Medium/slow flow rate: 84 mL/min/cm²

  • Thermal stability up to 500°C

  • Thickness: 0.35 mm | Weight: 75 g/m²

Common Applications

  • IgC and fine protein precipitate collection

  • Clarification of aggressive chemical solutions

  • TCLP testing (EPA Method 1311)

  • Environmental and regulatory sample analysis

  • HEPA-type air filtration

Whatman Equivalent: GF/F

Sterlitech Equivalent: Grade F

Millipore Equivalent: APFF

  • IgC and fine protein precipitate collection

  • Clarification of aggressive chemical solutions

  • TCLP testing (EPA Method 1311)

  • Environmental and regulatory sample analysis

  • HEPA-type air filtration

Specification

Grade: GF-75

Features & Applications: Most retentive grade. Suitable for collection of IgC and other very fine protein precipitates. Clarifies chemically aggressive solutions. Meets requirements for TCLP (EPA method 1311). HEPA type air filter.

Nominal Retention: 0.3 µm

Thickness: 0.35 mm

Weight (g/m²): 75

Water Flowa84

Max. Op. Temp.: 500°C

Binder: None

Whatman Equivalent: GF/F

a The time in seconds to filter 100 mL of distilled H20 at 20°C under pressure supplied by a 10 cm water column through a 10 cm² section of filter

HS Code / Commodity Code: 7019905140