Variation ID | Pack Size | List Price | Qty | ||
---|---|---|---|---|---|
photo_camera | 13mm x 100 Pack
GF7513MM-100 |
£119.16 | |||
photo_camera | 20mm x 100 Pack
GF7520MM-100 |
£119.16 | |||
photo_camera | 21mm x 100 Pack
GF7521MM-100 |
£119.16 | |||
photo_camera | 22mm x 100 Pack
GF7522MM-100 |
£119.16 | |||
photo_camera | 24mm x 100 Pack
GF7524MM-100 |
£119.16 | |||
photo_camera | 25mm x 100 Pack
GF7525MM-100 |
£119.16 | |||
photo_camera | 37mm x 100 Pack
GF7537MM-100 |
£150.02 | |||
photo_camera | 42.5mm x 100 Pack
GF7542.5MM-100 |
£166.15 | |||
photo_camera | 47mm x 100 Pack
GF7547MM-100 |
£157.25 | |||
photo_camera | 55mm x 100 Pack
GF7555MM-100 |
£213.93 | |||
photo_camera | 70mm x 100 Pack
GF7570MM-100 |
£239.17 | |||
photo_camera | 90mm x 100 Pack
GF7590MM-100 |
£326.34 | |||
photo_camera | 110mm x 100 Pack
GF75110MM-100 |
£481.18 | |||
photo_camera | 125mm x 100 Pack
GF75125MM-100 |
£585.49 | |||
photo_camera | 142mm x 100 Pack
GF75142MM-100 |
£698.95 | |||
photo_camera | 150mm x 100 Pack
GF75150MM-100 |
£837.86 | |||
photo_camera | 293mm x 50 Pack
GF75293MM-50 |
£1487.59 |
Advantec GF-75 Glass Fibre Filters – High Retention Filters for Protein Collection and TCLP Analysis
Advantec GF-75 glass fibre filters are binderless, fine-porosity filters designed for very fine particulate retention, including IgC collection, protein precipitates, and the clarification of chemically aggressive solutions. With a nominal retention of 0.3 µm, GF-75 is the highest retention grade in the Advantec range and is well-suited for applications where precision and purity are critical.
These filters meet the requirements of EPA Method 1311 (TCLP) and are comparable to Sterlitech Grade F and Millipore APFF. The binderless borosilicate construction ensures low extractables and thermal stability up to 500°C, making them ideal for both analytical and regulatory testing environments.
Binderless glass microfiber for high purity
Fine porosity with 0.3 µm nominal retention
Highest retention grade in the Advantec range
Medium/slow flow rate: 84 mL/min/cm²
Thermal stability up to 500°C
Thickness: 0.35 mm | Weight: 75 g/m²
IgC and fine protein precipitate collection
Clarification of aggressive chemical solutions
TCLP testing (EPA Method 1311)
Environmental and regulatory sample analysis
HEPA-type air filtration
Whatman Equivalent: GF/F
Sterlitech Equivalent: Grade F
Millipore Equivalent: APFF
IgC and fine protein precipitate collection
Clarification of aggressive chemical solutions
TCLP testing (EPA Method 1311)
Environmental and regulatory sample analysis
HEPA-type air filtration
Specification
Grade: GF-75
Features & Applications: Most retentive grade. Suitable for collection of IgC and other very fine protein precipitates. Clarifies chemically aggressive solutions. Meets requirements for TCLP (EPA method 1311). HEPA type air filter.
Nominal Retention: 0.3 µm
Thickness: 0.35 mm
Weight (g/m²): 75
Water Flowa: 84
Max. Op. Temp.: 500°C
Binder: None
Whatman Equivalent: GF/F
a The time in seconds to filter 100 mL of distilled H20 at 20°C under pressure supplied by a 10 cm water column through a 10 cm² section of filter
HS Code / Commodity Code: 7019905140