Variation ID | Product Code | Pack Size | List Price | Qty | ||
---|---|---|---|---|---|---|
photo_camera | HI-5522-02 | 1 Pack
HI-5522-02 |
£1221.20 |
HI-5522 is a high grade benchtop instrument that measures measures seven parameters and incorporates dual channels with a separate temperature probe input and support external reference electrodes required by half-cell pH sensors.
Up to four conductivity calibration points can be used to increase measurement accuracy:
HI-5522 is an ideal research-grade instrument with large easy read graphic display and soft touch keypad.
Customise to your application
The display is customisable and can display two channels simultaneously. Measurements are given in various modes: basic measurement, with or without GLP information, graph or logging data. Display colours are also selectable.
Up to 10 profiles (5 for each channel) can be saved and recalled for both meters eliminating the need to reconfigure each time a different electrode is used. User definable configurations include:
Measuring ISE with the HI-5522
HI-5522 uses incremental methods to measure ISE and deliver faster, more accurate determinations of ion concentration.
Sample concentrations are calculated automatically then logged into an ISE method report Save up to 200 reports for future recall Repeat process on multiple samples without re-entering sets of parameters Print reports using HI-92000 PC software
Incremental techniques help to reduce errors from variables such as temperature, viscosity, pH or ionic strength. The electrodes remain immersed during the process, reducing measurement time as well as eliminating samples carry over and associated error.
Known addition, known subtraction, analyte addition and analyte subraction methods are standard.
Precision analysis
pH CalCheck
HI-5522 can use EC probes for conductivity measurements required to prepare water for injection (WFI) according to USP <645>
User friendly
pH - Range | - | -2.0 to 20.0 pH; -2.00 to 20.00; -2.000 to 20.000 pH | ||||
Resolution | - | 0.1 pH; 0.01 pH; 0.001 pH | ||||
Accuracy | - | ±0.1 pH; ±0.01 pH; ±0.002 pH ± 1 LSD | ||||
Calibration | - | automatic, up to five-point calibration, eight standard buffers available, and five custom buffers | ||||
Temperature Compensation | - | automatic or manual from -20.0 to 120.0°C | ||||
mV - Range | - | ±2000 mV | ||||
Resolution | - | 0.1 mV | ||||
Accuracy | - | ±0.2 mV ± 1 LSD | ||||
ISE - Range | - | 1 x 10-6 to 9.99 x 1010 concentration | ||||
Resolution | - | 1; 0.1; 0.01; 0.001 concentration | ||||
Accuracy | - | ±0.5% (monovalent ions); ±1% (divalentions) | ||||
Calibration | - | automatic, up to five-point calibration, five fixed standard solutions available for each measurement unit, and five user efined standards | ||||
Temperature - Range | - | -20.0 to 120.0°C | ||||
Resolution | - | 0.1°C | ||||
Accuracy | - | ±0.2°C (without probe) | ||||
EC - Range | - | 0.000 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm absolute EC | ||||
Resolution | - | 0.001 uS/cm; 0.01 uS/cm; 0.1 uS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm | ||||
Accuracy | - | ±1% of reading (±0.01uS/cm) | ||||
Cell Constant | - | 0.0500 to 200.00 | ||||
Cell Type | - | 4 cells | ||||
Calibration | - | automatic standard recognition, user standard single point/multi-point calibration | ||||
Calibration Reminder | - | yes | ||||
Temperature Coefficient | - | 0.00 to 10.00%/°C | ||||
Temperature Compensation | - | disabled, linear and non-linear (natural water) | ||||
Reference Temperature | - | 5.0 to 30.0°C | ||||
Profiles | - | up to 10, 5 each channel | ||||
USP Compliant | - | yes | ||||
TDS - Range | - | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt actual TDS (with 1.00 factor) | ||||
Resolution | - | 0.001 ppm; 0. 01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt; 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt | ||||
Accuracy | - | ±1% of reading (±0.01 ppm) | ||||
Resistivity - Range | - | 1.0 to 99.9 Ω • cm; 100 to 999 Ω • cm; 1.00 to 9.99 KΩ • cm; 10.0 to 99.9 KΩ • cm; 100 to 999 KΩ • 1.00 to 9.99 M Ω •cm; 10.0 to 100.0 MΩ • cm | ||||
Resolution | 0.1 Ω •cm; 1 Ω • cm; 0.01 K Ω •cm; 0.1 K Ω •cm; 1 KΩ • cm; 0.01 MΩ • cm; 0.1 MΩ • cm | |||||
Accuracy | - | ±2% of reading (± 1 Ω • cm) | ||||
Salinity - Range | - | practical scale: 0.00 to 42.00 psu; natural sea water scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0% NaCl | ||||
Resolution | - | 0.01 for practical scalenatural sea water scale; 0.1% for percent scale | ||||
Accuracy | - | ±1% of reading | ||||
Calibration | - | percent-scale one point (with HI-7037 standard) | ||||
pH electrode | - | HI-1131B glass body pH electrode with BNC connector and 1m cable (included) | ||||
EC Probe | - | HI-76312 platinum, four-ring EC/TDS probe with a 1m cable (included) | ||||
Temperature Probe | - | HI-7662-T stainless steel temperature probe with 1m cable (included) | ||||
Input Channel (s) | - | 1 pH/ORP + 1 EC | ||||
GLP | - | cell constant, reference temperature/coefficient, calibration points, calibration time stamp, probe offset for conductivity | ||||
Logging | - | record: 100,000 data point storage/channel, up to 100 lots with max, 50,000 records/lot; Interval: settable between 1 second and max log time of 180 minutes; Type: automatic, manual, AutoHOLD | ||||
Display | - | colour graphic LCD with on-screen help, graphing, and custom colour configuration | ||||
PC Connection | - | USB | ||||
Power Supply | - | 12 VDC adapter (included) | ||||
Environment | - | 0 to 50°C; RH max 95% non-condensing | ||||
Dimensions/Weight | - | 160 x 231 x 94 mm/1.2 kg |