shopping_cart search menu
Meter, multiparameter, without probe, comes with charger and instructions 230VAC Group Picture

Meter, multiparameter, without probe, comes with charger and instructions 230VAC

Code: HI-9829-02
Revert
Product Code Pack Size List Price Qty  
HI-9829-02 1 Pack £2597.80
Revert
Pack: 1 Pack

£2597.80

The HI-9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters.

The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature.

The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use.

The HI-9829 is highly customisable and supplied with all necessary accessories, packaged in a durable carrying case.

 

  • Built in GPS Receiver
  • Colour Coded, field replaceable sensors
  • Waterproof protection
  • Logging – from probe to meter
  • Fast Tracker – Tag Identification system
  • Sensor Check - Auto-recognition of all sensors
  • GLP features – Meets good laboratory practices
  • Connectivity – PC compatible via USB
  • Help feature – On-screen user guides
  • Backlight – Backlit, graphic LCD display
  • Waterproof – waterproof casing

Meter with or without GPS

Built in GPS Receiver

  • 12 channel GPS receiver and antenna
  • Tracks location using satellites to within 30 feet
  • Latitude and longitude recorded with readings
  • Location naming for GPS coordinates
  • Distance from current location to stored location
  • HI-929829 software supplied integrates data collected with Google maps
  • Measurement readings including GPS coordinates
  • Date and time
  • Named locations and remarks
  • Sample number

 Two probes to choose from (Basic or Logging)

The HI-7609829 (basic) and HI-7629829 (logging) are multiparameter probes for use with the HI-9829 portable meter. It is an option to choose which probe will be supplied with the HI-9829. By default the HI-9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.

 HI-7629829 Autonomously Logging Probe

  • Same as basic probe but with logging capability
  • Logs data independent of HI-9829 meter
  • Operates on 4 “AA” batteries for up to 70 days*
  • Stores up to 140,000 single parameter readings or 35,000 for all parameters
  • Logs data from 1 second to 3 hours
  • Choose to be supplied with EC or EC/Turbidity sensor
  • Supplied with USB cable for direct connection to Window’s compatible PC 
  • *All channels logging at 10 minute intervals with no averaging 

HI-7609829 Basic Probe

  • Digital probe that is less than 2 inches in diameter
  • 3 colour-coded sensor inputs
  • IP68 rating for continuous immersion in water
  • Multistrand, multiconductor cable rated for 150 lbs (intermittent use)
  • Available with 4, 10, or 20 meter cable
  • Weighted shield protects all sensors 

Cable lengths 

  • The probes are available with a choice of cable lengths: 4m, 10m and 20m
  • DIN connection
  • Logging probes can be connected directly to a PC with the HI-76982910 USB adaptor cable and HI-929829 PC application software to download log files directly. 

 

On screen features

GPS Option

The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data. 

Quick Calibration

The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps. 

Graphing Capability

Trend graphing with sample date and time may be viewed on the display or transferred to PC. 

Features:

Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.

Backlit Dot Matrix LCD Display – The HI-9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.

Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.

Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.

Auto-sensor Recognition - The probe and meter automatically recognise the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.

Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.

Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.

Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.

GLP Data – HI-9829 includes a GLP feature that allows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.

Data Logging – The HI-9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.

Graphing Capability - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.

PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI-7698291 USB adapter and HI-929829 software.

Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C“ NiMH rechargeable batteries that provide up to 140 hours of battery life*.

Rugged thermoformed carrying case – The HI-9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.

* Without GPS or turbidity measurements 

Fast Tracker—Tag Identification System

HANNA’s Fact Tracker—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labelled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker system complements the GPS for ultimate tracking. 

iButton. Tags are Easy to Install

Install the optional TAGs near your sampling points for quick and easy iButton readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.

HI-9829 specification with/without GPS -  
Temperature Compensation - Automatic from -5 to 55°C 
     
Models with GPS - 12 Channel Receiver, 10m range
     
Logging memory from meter - 44,000 records44,000 records
     
Logging interval - 1 second to 3 hours
     
Computer interface - USB (with HI-929829)
     
FastTracker TAG ID - Yes
     
Waterproof protection - IP67
     
Environment - 0 to 50°C, RH 100%
     
Power supply - 1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter
     
Dimensions - 221 x 115 x 55mm
     
Weight - 750g
     
Maximum Probe Immersion - Depth – 20 metres
     
HI-9829 parameter specifications    
     
pH Range - 0.00 to 14.00 pH
     
pH Resolution - 0.01 pH
     
pH Accuracy -  0.02 pH
     
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
     
mV Range ±600.0 mV
     
mV Resolution - 0.1 mV
     
mV accuracy ±0.5 mV
     
ORP Range ±2000 mV
     
ORP Resolution - 0.1 mV
     
ORP Accuracy ±1.0 mV
     
ORP Calibration - automatic at one custom point (relative mV)
     
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
     
EC Resolution - Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
     
EC Accuracy ±1% of reading or ±1 µS/cm whichever is greater
     
EC Calibration automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
     
TDS Range 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
     
TDS Resolution Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
     
TDS Accuracy - ±1% of reading or ±1 ppm (mg/L), whichever is greater
     
TDS Calibration based on conductivity or salinity calibration
     
Resistivity Range - 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
     
Resistivity Resolution dependent on resistivity reading
     
Resistivity Calibration based on conductivity calibration
     
Salinity Range 0.00 to 70.00 PSU
     
Salinity Resolution 0.01 PSU
     
Salinity Accuracy - ±2% of reading or ±0.01 PSU whichever is greater
     
Salinity Calibration based on conductivity calibration
     
Seawater σ Range 0.0 to 50.0 σt, σ0, σ15
     
Seawater σ Resolution 0.1 σt, σ0, σ15
     
Seawater σ Accuracy ±1 σt, σ0, σ15
     
Seawater σ Calibration based on conductivity or salinity calibration
     
Ammonium-Nitrogen Range 0.02 to 200.0 ppm Am (as NH4 +-N)
     
Ammonium-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
     
Ammonium-Nitrogen Accuracy ±5 % reading or 2 ppm
     
Ammonium-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
     
Chloride Range 0.6 to 200.0 ppm Cl (as Cl- )
     
Chloride Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
     
Chloride Accuracy ±5 % of reading or 2 ppm
     
Chloride Calibration 1 or 2 point, 10 ppm and 100 ppm
     
Nitrate-Nitrogen Range - 0.62 to 200.0 ppm Ni (as NO3 - -N)
     
Nitrate-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
     
Nitrate-Nitrogen Accuracy - ±5 % of reading or 2 ppm
     
Nitrate-Nitrogen Calibration - 1 or 2 point, 10 ppm and 100 ppm
     
Turbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNU
     
Turbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
     
Turbidity Accuracy ±0.3 FNU or ±2 % of reading, whichever is greater
     
Turbidity Calibration Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
     
DO Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
     
DO Resolution 0.1%; 0.01 ppm (mg/L)
     
DO Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
     
DO Calibration automatic one or two points at 0 and 100% or one custom point
     
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
     
Atmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
     
Atmospheric Pressure Accuracy ±3 mm Hg within ±15°C from the temperature during calibration
     
 Atmospheric Pressure Calibration - automatic at one custom point