shopping_cart search menu
Meter, HI 9829, with GPS Group Picture

Meter, HI 9829, with GPS

Code: HI-9829-13042
Revert
Product Code Pack Size List Price Qty  
HI-9829-13042 1 Pack £5181.35
Revert
Pack: 1 Pack

£5181.35

Designed for measuring water quality, this advanced professional multiparameter measures up to 15 parameters and comes with an impressive range of features. These include a fully integrated GPS system and an autonomous sensor for measuring pH, EC/Turbidity, DO and temperature on a 4m cable.

 

Main benefits

 

Display 1 - 12 parameters simultaneously from up to 15 selectable parameters Fast Track data traceability and/or GPS positioning Robust, intelligent logging probe with stainless steel tip and narrow diameter for wells and pipes Field replaceable sensors Clear screen with backlit graphics making it easy to read - even in low light levels Rugged water resistant casing - ideal for harsh outdoor environments Ergonomic design that is comfortable to hold and use Context sensitive HELP menu Information and instructions in plain text Flexible user interface allows users to configure the meter to suit individual needs

 

Integrated GPS Positioning

 

Measurement locations can be tracked and logged with detailed co-ordinates to make it easier than ever to return to the same location for repeated data collection.

The GPS co-ordinates are displayed on screen with up to 10 measurement parameters and are recorded with logged data. Users can connect to GPS tracking software such as Google Maps to view locations where samples have been taken. Measurement information is then shown on the map on screen.

The GPS can be used in conjunction with Fast Track for ultimate tracking and data capture.

 

Fast Track Tag Identification System

 

Using an iButton data management system that connects to iButton tags installed at all sampling sites, users can log and label measurements with an alpha-numeric location ID.

Data is automatically captured by the meter and can be transferred accurately and efficiently to a PC for evaluation and analysis.

 

Intelligent Potentiometric Probe

 

Designed as a professional tool, the digital probe provides stable, noise-free sensor signal management without the need for pre-amplified pH sensors.

Key features include;

 

Conductivity/Turbidity sensor according to EN ISO 7027 Independent probe with data acquisition allowing on-site measurement, collection and data storage Rugged and water resistant to IP67 with weighted end Automatic recognition of sensors and electrodes Field replaceable sensors

 

Applications

 

The HI-9829 is a high specification meter designed for taking professional field measurements in lakes, rivers and seas.

 

Aquaculture Fish farming Oceanography Harbours and Ports Surface, drainage and waste water testing.

HI-9829 specification with/without GPS    
     
Temperature Compensation Automatic from -5 to 55°C
     
Models with GPS 12 Channel Receiver, 10m range
     
Logging memory from meter 44,000 records 
     
Logging interval 1 second to 3 hours
     
Computer interface USB (with HI-929829)
     
FastTracker TAG ID Yes
     
Waterproof protection IP67 
     
Environment 0 to 50°C, RH 100%
     
Power supply 1.5 V Alkaline C cells (4)/1.2V NiMH rechargeable C Cells (4) USB, 12V power adapter
     
Dimensions 221 x 115 x 55mm
     
Weight 750g
     
Maximum Probe Immersion Depth – 20 metres
     
HI-9829 parameter specifications    
     
pH Range 0.00 to 14.00 pH
     
pH Resolution 0.01 pH
     
pH Accuracy ±0.02 pH
     
pH Calibration automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
     
mV Range ±600.0 mV
     
mV Resolution 0.1 mV
     
mV accuracy ±0.5 mV
     
ORP Range ±2000 mV
     
ORP Resolution 0.1 mV
     
ORP Accuracy ±1.0 mV
     
ORP Calibration automatic at one custom point (relative mV)
     
EC Range - 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
     
EC Resolution - Manual: 1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm, Automatic: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm, Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm
     
EC Accuracy - ±1% of reading or ±1 µS/cm whichever is greater
     
EC Calibration - automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point 
     
TDS Range - 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
     
TDS Resolution - Manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L), Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L), Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
     
TDS Accuracy - ±1% of reading or ±1 ppm (mg/L), whichever is greater
     
TDS Calibration - based on conductivity or salinity calibration
     
Resistivity Range 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm
     
Resistivity Resolution - dependent on resistivity reading
     
Resistivity Calibration based on conductivity calibration
     
Salinity Range 0.00 to 70.00 PSU
     
Salinity Resolution 0.01 PSU
     
Salinity Accuracy ±2% of reading or ±0.01 PSU whichever is greater
     
Salinity Calibration based on conductivity calibration
     
Seawater σ Range 0.0 to 50.0 σt, σ0, σ15
     
Seawater σ Resolution 0.1 σt, σ0, σ15
     
Seawater σ Accuracy ±1 σt, σ0, σ15
     
Seawater σ Calibration based on conductivity or salinity calibration
     
Ammonium-Nitrogen Range 0.02 to 200.0 ppm Am (as NH4 +-N)
     
Ammonium-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
     
Ammonium-Nitrogen Accuracy ±5 % reading or 2 ppm
     
Ammonium-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
     
Chloride Range 0.6 to 200.0 ppm Cl (as Cl- )
     
Chloride Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm
     
Chloride Accuracy ±5 % of reading or 2 ppm
     
Chloride Calibration 1 or 2 point, 10 ppm and 100 ppm
     
Nitrate-Nitrogen Range 0.62 to 200.0 ppm Ni (as NO3 - -N)
     
Nitrate-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm
     
Nitrate-Nitrogen Accuracy ±5 % of reading or 2 ppm
     
Nitrate-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppm
     
Turbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNU
     
Turbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU
     
Turbidity Accuracy - ±0.3 FNU or ±2 % of reading, whichever is greater
     
Turbidity Calibration - Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom
     
DO Range - 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)
     
DO Resolution - 0.1%; 0.01 ppm (mg/L)
     
DO Accuracy 0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg/L): ±1.5% of reading or ±0.10 ppm (mg/L), whichever is greater, 30.00 ppm (mg/L) to 50.00 ppm (mg/L): ±3% of reading, 300.0 to 500.0% saturation: ±3% of reading
     
DO Calibration - automatic one or two points at 0 and 100% or one custom point
     
Atmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa
     
Atmospheric Pressure Resolution - 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa
     
Atmospheric Pressure Accuracy - ±3 mm Hg within ±15°C from the temperature during calibration
     
Atmospheric Pressure Calibration - automatic at one custom point

You may also like...

pH Calibration Buffer Solution traceable to NIST, Red, pH 4.0

pH Calibration Buffer Solution traceable to NIST, Yellow, pH 7.0